sledge
New member
I had what I thought was a Big Problem about a week ago. I was riding to town, about 20 miles, when I hit a small bump at the end of a small concrete bridge and every light on my Spyder went out. I thought a wire had fallen off maybe, so I just kept going to town, maybe 3 miles farther, and the Check Eng light started flashing and the Parking brake was on, it said so on my dash. Sooooo, I turned around and took the Spyder back home and drove the car to town. A few days later, went out to my Garage and started looking for a Wire hanging loose maybe ... Nothing ... Checked the Oil ... Full ... Checked Antifreeze ... Full ... So, I started with a good Volt/Ohm meter, checking everything 1 at a time. Under the seat ... everything was right; then to the Frunk and the Fuse Box ... It just so Happened that I started on the top row on the left at the # 1 fuse ... 15 Amp - and it was blown! I picked a new 15 Amp fuse out of my box, put it in there ... and in 1 second, EVERYTHING was perfect ... LOL! I made a living most of my life as some kind of Mechanic and I never saw anything on any kind of Car, Truck, motorcycle, boat, nothing like that before! Soo, just in case any of you folks ever have that kind of problem, check that little 15 Amp # 1 fuse first!
Last edited by a moderator: